Products

  • GDZL-50L Oil Filtration Machine

    GDZL-50L Oil Filtration Machine

    The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment.

     

  • Battery Discharge Tester

    Battery Discharge Tester

    GDBD Series intelligent battery discharge test system is used for monitoring single battery’s voltage. When the battery is offline, the tester can work as a discharge load to realize constant current discharge of the set value by continuously regulating the discharge current.

  • GDYB-S6 Three Phase Energy Meter Test Bench

    GDYB-S6 Three Phase Energy Meter Test Bench

    GDYB series Single/Three Phase Energy Meter Test Bench is used to measure various kinds of single/three phase meters of 0.1% and below. It has good appearance, complete functions and excellent performance.

  • GDYB-S20 Three Phase Energy Meter Test System

    GDYB-S20 Three Phase Energy Meter Test System

    GDYB series Three Equal Potential Multi-function Electric Energy Meter Test System is well-developed third generation electronic programmable three phase electric energy meter multifunctional test system according to the latest national standards and regulations.

     

  • GDJB-6000D Smart Substation Relay Protection Test System

    GDJB-6000D Smart Substation Relay Protection Test System

    GDJB-6000D Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to the technical specifications related to “DL/T 624-2010 Relay Protection Micro-type Test Device Technical Conditions”, and based on IEC61850 communication standard, realized by using advanced computer technology.

  • GDB-P Auto Transformer Turns Ratio Tester

    GDB-P Auto Transformer Turns Ratio Tester

    According to IEC and the relevant national standards, transformer turns ratio test is a necessary project in the process of power transformer production, user handover and maintenance test.

     

  • GDSL-BX-200 Primary Current Injection Test Set

    GDSL-BX-200 Primary Current Injection Test Set

    GDSL-BX-200 Primary Current Injection Test Set, is mainly used in calibration for current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc. 

  • GDWR-5A Earth Resistance Tester for Ground Grid

    GDWR-5A Earth Resistance Tester for Ground Grid

    GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy.

  • GDJR-200D Single Phase Electronic Thermal Relay Calibrator

    GDJR-200D Single Phase Electronic Thermal Relay Calibrator

    GDJR-200D Single Phase Electronic Thermal Relay Calibrator is mainly used for the setting and verification of various electrical equipment. With features of reasonable design, convenient operation and large output power, it is widely used in electric test sites of power system, railway, petrochemical, metallurgy and mining enterprises.

  • GD8000C SF6 Gas Leak Online Monitoring System

    GD8000C SF6 Gas Leak Online Monitoring System

    GD8000C quantitatively leak online monitoring system is mainly used in the 35KV SF6 switch room and 500KV, 220KV, 110KV GIS room in the substation to monitor the SF6 gas leakage in the SF6 combined electrical equipment room environment and the oxygen content in the air in real time.

  • GDRB-C Power Transformer Winding Deformation Tester

    GDRB-C Power Transformer Winding Deformation Tester

    Power transformer winding deformation tester (frequency response method) is based on the measurement of characteristic parameters of transformer internal windings, adopts the internal fault frequency response analysis (FRA) method, can accurately judge the internal faults of transformers.

     

     

  • GDDJ-HVC Dielectric Loss Tester for Live Capacitive Equipment

    GDDJ-HVC Dielectric Loss Tester for Live Capacitive Equipment

    There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection.