GDHG-201P CT/PT Analyzer

GDHG-201P CT/PT Analyzer

Brief Description:

GDHG-201P CT/PT Analyzer is a lightweight, portable unit capable of testing both current and voltage transformers.

  • CT testing includes Excitation Characteristic Test, Knee Points, Turn Ratio, Polarity, Secondary Winding Resistances, Secondary Burden,Ratio Error, Angular Difference
  • VT testing including Excitation Characteristic Test, Knee Points, Turn Ratio, Polarity, Secondary Winding Resistances, Ratio Error, Angular Difference

 

 

 


Product Detail

Product Tags

GDHG-201P
Features
  • Ability to test both VT and CT
  • CT Knee points up to 60kV
  • Small and light unit suitable for on-site test
  • Test results can be download by USB disk.
  • Highest measurement accuracy: Max. Ratio error ±0.05 %
  • Max. Angular error ±2min
  • Turns ratio range is 1-40000.
  • 5.7inch LCD screen display.
  • Storage 1000 groups data
  • Meets IEC60044-1, IEC60044-6 standards of all kinds of CT/PT.
  • Using variable frequency method to test VA curves and 10% error curve of CT/TP.
  • Max. Output is 180V and 12A rms (36A peak value)

Specifications
Model GDHG-201P
Application CT, PT
Output 0~180Vrms, 12Arms, 36A(Peak Value)
Voltage Measuring Precision ±0.1%
CT Turns Ratio Test Range 1~40000
Precision ±0.05%
PT Turns Ratio Test Range 1~40000
Precision ±0.5%
Phase Test Range ±2 min
Precision 0.5 min
Secondary winding resistance Test Range 0~30
Precision 0.22
AC burden Test Range 0~1000VA
Precision 0.20.02VA
Input voltage AC220V±10%, 50Hz
Working environmental Temperature: -10℃~50℃, Humidity: ≤90%
Dimension & Weight 365*290*153mm, 10kg
Accessories
Host 1 piece
Power cord 1 piece
Red test cable 1 piece
Yellow test cable 1 piece
Green test cable 1 piece
Ground cable 1 piece
Alligator clip (Jaw 12mm) 4 pieces
Alligator clip (Jaw 20mm) 2 pieces
Inserting piece 4 pieces
Print paper 4 rolls
disk 1 piece
Fuse 10A 5 pieces
Special screwdriver for fuse 1 piece
Users guide 1 copy
Warranty period 1 copy
Packing list 1 copy
Factory test report 1 copy

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us